| Safety |
UL/CSA 62368-1, EN/IEC 62368-1, IS 13252 (PART 1): 2010/IEC 60950-1: 2005 |
| Hazardous |
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31), IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31),; EAC EX (TR CU 012/2011), INMETRO (ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC; 60079-31), UK Ex (EN IEC 60079-0, EN 60079-1, EN 60079-31), KCs (Employment and labor |
| Environmental and Performance |
EN/IEC 60529: IP66, IP67, IP68, IP69 |
| EN 60068-2-52: salt spray |
UL50E: 4X, 6P |
| Electromagnetic Emissions |
FCC Part 15 Subpart B Class A, IC ICES-003 Class A, EN 55032 Class A, EN 61000-6-3 |
| Electromagnetic Immunity |
EN 50130-4 |
| Vibration Test |
EN 50130-5, EN 60068-2-6 |
| Warranty |
3-year limited warranty. 5-year extended warranty is available. |
| Temperature |
EXF2230-52-C4 |
| II 2 G Ex db IIC T5 Gb |
II 2 D Ex tb IIIC T100°C Db IP66/IP68 |
| -50°C ≤Ta ≤ |
+65°C |
| +80°C |
IECEx ITS 15.0030X |
| Ex db IIC T5 Gb |
Ex tb IIIC T100°C Db IP66/IP68 |
| INMETRO UL BR 16.0004X |
Ex db IIC T5 Gb |
| EAC Ex RU C-IT.H |
A91.B.00274/22 |
| 1Ex db IIC T5 Gb X |
Ex tb IIIC T100°C Db X |
| UK Ex – ITS21UKEX0379X |
II 2 G Ex db IIC T5 Gb |
| II 2 D Ex tb IIIC T100°C Db IP66/IP68 |
KCs 19-KA4BO-0180X, 19- |
| KA4BO-0181X |
Ex db IIC T5 Gb |
| Ex tb IIIC T100°C Db |
cETLus 5002689 Hazardous |
| Location America |
Class I Zone 1 AEx db IIC T5 Gb |
| Zone 21 AEx tb IIIC T100°C Db |
Class I Div 2 Group A,B,C & D T5 |
| Class II Div 2 Group F & G T100°C |
cETLus 5002689 Hazardous |
| Location Canada |
Ex tb IIIC T100°C Db |
| Class I Div 2 Group A,B,C & D T5 |
Class II Div 2 Group F & G T100°C |
| ATEX ITS15ATEX18330X |
II 2 G Ex db IIC T6 Gb |
| II 2 D Ex tb IIIC T85°C Db IP66/IP68 |
-50°C ≤Ta ≤ |
| +55°C |
+80°C |
| IECEx ITS 15.0030X |
Ex db IIC T6 Gb |
| Ex tb IIIC T85°C Db IP66/IP68 |
INMETRO UL BR 16.0004X |
| Ex db IIC T6 Gb |
Ex tb IIIC T85°C Db IP66/IP68 |
| EAC Ex RU C-IT.H |
A91.B.00274/22 |
| 1Ex db IIC T6 Gb X |
Ex tb IIIC T85°C Db X |
| UK Ex – ITS21UKEX0379X |
II 2 G Ex db IIC T6 Gb |
| II 2 D Ex tb IIIC T85°C Db IP66/IP68 |
KCs 19-KA4BO-0180X, 19- |
| KA4BO-0181X |
Ex db IIC T6 Gb |
| Ex tb IIIC T85°C Db |
cETLus 5002689 Hazardous |
| Location America |
Class I Zone 1 AEx db IIC T6 Gb |
| Zone 21 AEx tb IIIC T85°C Db |
Class I Div 2 Group A,B,C & D T6 |
| Class II Div 2 Group F & G T85°C |
cETLus 5002689 Hazardous |
| Location Canada |
Ex db IIC T6 Gb |
| Ex tb IIIC T85°C Db |
Class I Div 2 Group A,B,C & D T6 |
| Temperature |
EXF22302B-C4 |
| II 2 G Ex db IIC T6…T5 Gb |
II 2D Ex tb IIIC T85°C…T100°C Db |
| -50°C ≤Ta ≤ |
+55°C or +65°C |
| +80°C |
IECEx ITS 15.0030X |
| Ex db IIC T6…T5 Gb |
Ex tb IIIC T85°C…T100°C Db; cETLus 5002689 |
| Hazardous Location America |
Class I Zone 1 AEx db IIC T6…T5 Gb |
| Zone 21 AEx tb IIIC T85°C…T100°C Db |
Class I Div 2 Group A,B,C & D T6…T5 |
| Class II Div 2 Group F & G |
T85°C…T100°C; cETLus 5002689 |
| Hazardous Location Canada |
Ex db IIC T6…T5 Gb |
| Ex tb IIIC T85°C…T100°C Db |
Class I Div 2 Group A,B,C & D T6…T5 |
| Class II Div 2 Group F & G |
T85°C…T100°C |
| Ts mark |
Ex db IIC T6…T5 Gb |
| Temperature |
EXF2230-52-A4 |
| II 2 G Ex db IIC T5 Gb |
II 2 D Ex tb IIIC T100°C Db IP66/IP68 |
| -60°C ≤Ta ≤ |
+65°C |
| +80°C |
IECEx ITS 15.0030X |
| Ex db IIC T5 Gb |
Ex tb IIIC T100°C Db IP66/IP68 |
| INMETRO UL BR 16.0004X |
Ex db IIC T5 Gb |
| EAC Ex RU C-IT.H |
A91.B.00274/22 |
| 1Ex db IIC T5 Gb X |
Ex tb IIIC T100°C Db X |
| UK Ex – ITS21UKEX0379X |
II 2 G Ex db IIC T5 Gb |
| II 2 D Ex tb IIIC T100°C Db IP66/IP68 |
EXF2230-62-A4 |
| II 2 G Ex db IIC T6 Gb |
II 2 D Ex tb IIIC T85°C Db IP66/IP68 |
| -60°C ≤Ta ≤ |
+55°C |
| +80°C |
IECEx ITS 15.0030X |
| Ex db IIC T6 Gb |
Ex tb IIIC T85°C Db IP66/IP68 |
| INMETRO UL BR 16.0004X |
Ex db IIC T6 Gb |
| EAC Ex RU C-IT.H |
A91.B.00274/22 |
| 1Ex db IIC T6 Gb X |
Ex tb IIIC T85°C Db X |
| UK Ex – ITS21UKEX0379X |
II 2 G Ex db IIC T6 Gb; II 2 D Ex tb IIIC T85°C Db IP66/IP68 |
| Temperature |
EXF22302A-A4 |
| II 2 G Ex db IIC T6…T5 Gb |
II 2D Ex tb IIIC T85°C…T100°C Db |
| -60°C ≤Ta ≤ |
+55°C or +65°C |
| +80°C |
IECEx ITS 15.0030X |
| Ex db IIC T6…T5 Gb |
Ex tb IIIC T85°C…T100°C Db; cETLus 5002689 Hazardous |
| Location America |
Class I Zone 1 AEx db IIC T6…T5 Gb |
| Zone 21 AEx tb IIIC T85°C…T100°C Db |
Class I Div 2 Group A,B,C & D T6…T5 |
| Class II Div 2 Group F & G |
T85°C…T100°C; cETLus 5002689 Hazardous |
| Location Canada |
Ex db IIC T6…T5 Gb |
| Ex tb IIIC T85°C…T100°C Db |
Class I Div 2 Group A,B,C & D T6…T5 |
| Class II Div 2 Group F & G |
T85°C…T100°C |
| Ts mark |
Ex db IIC T6…T5 Gb |
| Image Health |
Detects incremental changes in the cameras view, such as position shifts or obstructions. Notifies; users through ONVIF conformant events and summarized email reports. |