| Safety |
UL 62368-1, CSA 62368-1, IEC/EN 62368-1, IEC/EN 62471, IS13252(PART1):2010/IEC60950-1:2005 |
| Hazardous |
ATEX (EN IEC 60079-0, EN 60079-1, EN 60079-31), IECEx (IEC 60079-0, IEC 60079-1, IEC 60079-31),; INMETRO (ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-1, ABNT NBR IEC 60079-31),; UK Ex (EN IEC 60079-0, EN 60079-1, EN 60079-31), KCs (Employment and labor department 2021-22), |
| Environmental and Performance |
UL/CSA/IEC 60950-22, IEC 62262 Impact Rating (enclosure only), IEC 60529 IP69 Weather Rating,; IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-30, IEC 60068-2-52; NEMA TS 2 para 2.2.7 – 2.2.9, Type 4X and 6P |
| Electromagnetic Emissions |
FCC Part 15 Subpart B Class A, IC ICES-003 Class A, EN 55032 Class A, EN 61000-6-4, EN 61000-3-2, |
| EN 61000-3-3 |
Electromagnetic Immunity; EN 50130-4 |
| Vibration test |
EN 50130-5, EN 60068-2-6 |
| Warranty |
3-year limited warranty. 5-year extended warranty is available. |
| temperature |
UL 23 ATEX 3004X |
| Ex II 2G Ex db IIB+H2 T5 Gb |
Ex II 2D Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+81°C |
| Ex II 2G Ex db IIC T6 Gb |
Ex II 2D Ex tb IIIC T85°C Db |
| -40°C ≤Ta ≤+60°C |
+80°C |
| EXPP – Certifications and Marking |
IECEx ULD 23.0012X |
| Ex db IIB+H2 T5 Gb |
Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+81°C |
| Ex db IIC T6 Gb |
Ex tb IIIC T85°C Db |
| -40°C ≤Ta ≤+60°C |
+80°C |
| UK Ex – UL23UKEX2846X |
Ex II 2G Ex db IIB+H2 T5 Gb |
| Ex II 2D Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +81°C |
Ex II 2G Ex db IIC T6 Gb |
| Ex II 2D Ex tb IIIC T85°C Db |
-40°C ≤Ta ≤+60°C |
| +80°C |
KCs 24 – KA4BO-0030X – 24- |
| KA4BO-0031X |
Ex db IIB+H2 T5 Gb |
| Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +81°C |
KCs 24 – KA4BO-0029X – 24- |
| KA4BO-0031X |
Ex db IIC T6 Gb |
| Ex tb IIIC T85°C Db |
-40°C ≤Ta ≤+60°C |
| +80°C |
INMETRO UL-BR 24.0211X |
| Ex db IIB+H2 T5 Gb |
Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+81°C |
| Ex db IIC T6 Gb |
Ex tb IIIC T85°C Db |
| -40°C ≤Ta ≤+60°C |
+80°C; cULus E319666 Hazardous |
| Location America |
Class I, Zone 1, AEx db IIB+H2 T5 Gb |
| Zone 21, AEx tb IIIC T100°C Db |
Class I, Div 2, Group B, C, D T5 |
| Class II, Div 2, Group F, G T5 |
-40°C ≤Ta ≤+70°C |
| +81°C |
Class I, Zone 1, AEx db IIC T6 Gb |
| Zone 21, AEx tb IIIC T85°C Db |
Class I, Div 2, Group A, B, C, D T6 |
| Class II, Div 2, Group F, G T6 |
-40°C ≤Ta ≤+60°C |
| +80°C |
cULus E319666 Hazardous |
| Location Canada |
Ex db IIB+H2 T5 Gb X |
| Ex tb IIIC T100°C Db X |
Class I, Div 2, Group B, C, D T5 |
| Class II, Div 2, Group F, G T5 |
-40°C ≤Ta ≤+70°C |
| +81°C |
Ex db IIC T6 Gb X |
| Ex tb IIIC T85°C Db X |
Class I, Div 2, Group A, B, C, D T6 |
| Class II, Div 2, Group F, G T6 |
-40°C ≤Ta ≤+60°C; +80°C |
| TS mark |
Ex db IIB+H2 T5 Gb |
| Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +81°C |
Ex db IIC T6 Gb |
| Ex tb IIIC T85°C Db |
-40°C ≤Ta ≤+60°C; +80°C |
| Cable entry temperature |
UL 23 ATEX 3004X |
| Ex II 2G Ex db IIB+H2 T5 Gb |
Ex II 2D Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+82°C |
| Ex II 2G Ex db IIC T6…T5 Gb |
Ex II 2D Ex tb IIIC T85°C…T100°C Db |
| -40°C ≤Ta ≤+55°C or +60°C |
+80°C |
| IECEx ULD 23.0012X |
Ex db IIB+H2 T5 Gb |
| Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +82°C |
Ex db IIC T6…T5 Gb |
| Ex tb IIIC T85°C…T100°C Db |
-40°C ≤Ta ≤+55°C or +60°C |
| +80°C |
UK Ex – UL23UKEX2846X |
| Ex II 2G Ex db IIB+H2 T5 Gb |
Ex II 2D Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+82°C |
| Ex II 2G Ex db IIC T6…T5 Gb |
Ex II 2D Ex tb IIIC T85°C…T100°C Db |
| -40°C ≤Ta ≤+55°C or +60°C |
+80°C |
| KCs 24-KA4BO-0026X – 24-A4BO- |
0028X |
| Ex db IIB+H2 T5 Gb |
Ex tb IIIC T100°C Db |
| -40°C ≤Ta ≤+70°C |
+82°C |
| KCs 24-KA4BO-0027X – 24- |
KA4BO-0028X |
| Ex db IIC T6…T5 Gb |
Ex tb IIIC T85°C…T100°C Db |
| -40°C ≤Ta ≤+55°C or +60°C |
+80°C |
| INMETRO UL-BR 24.0211X |
Ex db IIB+H2 T5 Gb |
| Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +82°C |
Ex db IIC T6…T5 Gb |
| Ex tb IIIC T85°C…T100°C Db |
-40°C ≤Ta ≤+55°C or +60°C |
| +80°C |
cULus E319666 Hazardous |
| Location America |
Class I, Zone 1, AEx db IIB+H2 T4 Gb |
| Zone 21, AEx tb IIIC T135°C Db |
Class I, Div 2, Group B, C, D T4 |
| Class II, Div 2, Group F, G T4 |
-40°C ≤Ta ≤+70°C |
| +84°C |
Class I, Zone 1, AEx db IIC T4 Gb |
| Zone 21, AEx tb IIIC T135°C Db |
Class I, Div 2, Group A, B, C, D T4 |
| Class II, Div 2, Group F, G T4 |
-40°C ≤Ta ≤+60°C |
| +80°C |
cULus E319666 Hazardous |
| Location Canada |
Ex db IIB+H2 T4 Gb X |
| Ex tb IIIC T135°C Db X |
Class I, Div 2, Group B, C, D T4 |
| Class II, Div 2, Group F, G T4 |
-40°C ≤Ta ≤+70°C |
| +84°C |
Ex db IIC T4 Gb X |
| Ex tb IIIC T135°C Db X |
Class I, Div 2, Group A, B, C, D T4 |
| Class II, Div 2, Group F, G T4 |
-40°C ≤Ta ≤+60°C; +80°C |
| TS mark |
Ex db IIB+H2 T5 Gb |
| Ex tb IIIC T100°C Db |
-40°C ≤Ta ≤+70°C |
| +82°C |
Ex db IIC T6…T5 Gb |
| Ex tb IIIC T85°C…T100°C Db |
-40°C ≤Ta ≤+55°C or +60°C; +80°C |